2022
S. Emery, S. Greene, Y. Chun, M. Elsisy, K. Chung, N. Hazen, S. Ye, S. Kim, W. Wagner (2022), In vitro and in vivo assessment of a novel ultra-flexible ventriculoamniotic shunt for treating fetal hydrocephalus, Journal of Biomaterials Applications, 2022.
2021
M. Elsisy, M. Shayan, Y. Chen, B. W. Tillman, C. Go, and Y. Chun (2021), Assessment of mechanical and biocompatible performance of ultra-large nitinol endovascular devices fabricated via a low-energy laser joining process, Journal of Biomaterials Applications, p. 08853282211019517, 2021.
2020
Emery SP, Greene S, Murdoch G, Wiley CA (2020). Histologic appearance of iatrogenic hydrocephalus in the fetal lamb model. Fetal Diagn Ther. 47(1):7-14 PMID 30974442
Emery SP, Narayanan S, Greene S (2020). Fetal Aqueductal stenosis: Prenatal diagnosis and intervention. Prenat Diagn 2020. Jan;40(1):58-65 PMID 31306500
C. Go, M. Elsisy, Y. Chun, P. Thirumala, W. Clark, S. Cho, A. Demetris, BW Tillman, (2020). A three-tier Rescue stent improves outcomes over balloon occlusion in a porcine model of noncompressible hemorrhage. Journal of Trauma and Acute Care Surgery, 89(2), pp. 320-328.
M. Elsisy, B. W. Tillman, C. Go, J. Kuhn, S. K. Cho, W. Clark, J. Park, and Y. Chun (2020). Comprehensive Assessment of Mechanical Behavior of an Extremely Long Stent Graft to Control Hemorrhage in Torso. Journal of Biomedical Materials Research Part B: Applied Biomaterials, pp. 1-12.
2018
C. Go, Y. Chun, J. Kuhn, Y. Chen, S.K. Cho, W.C. Clark, B.W. Tillman (2018), Damage control of caval injuries in a porcine model using a retrievable Rescue stent. Journal of Vascular Surgery: Venous and Lymphatic Disorders, 6(5), pp.646-656.
Tonetti DA, Richter B, Andrews E, Xu C, Emery SP, Greene S (2018). Clinical outcomes of congenital Aqueductal stenosis. World Neurosurgery 2018; 114: e976-e981. PMID 29588243
A. May, R. Orizondo (2018). Acute In Vivo Evaluation of the Pittsburgh Pediatric Ambulatory Lung, ASAIO Journal.
2017
Y. Chun, S. K. Cho, W. C. Clark, W. R. Wagner, X. Gu, A. D. Tevar, R. M. McEnaney, and B. W. Tillman (2017). J A retrievable rescue stent graft and radiofrequency positioning for rapid control of noncompressible hemorrhage. Trauma Acute Care Surg, 83(2), 249-255.
P. Fontes (2017). The Evolution of Oxygen Carrier Solutions for Machine Perfusion, Transplant Journal, volume 101 number 11.
E. Kocylidrim, N. Cardenes (2017). The Use of GMP-Produced Bone Marrow-Derived Stem cells in Combination with Extracorporeal Membrane and Oxygenation in ARDS: An Animal Model, ASIO Journal.
S. Madhani, B. Frankowski (2017). In Vitro and In Vivo Evaluation of a Novel Integrated Wearable Artificial Lung, The Journal of Heart and Lung Transplantation.
2016
B.W. Tillman, Y. Chun, S.K. Cho, Y. Chen, N. Liang, W.C. Clark, T. Maul, A. Demetris, X. Gu, W.R. Wagner, and A.D. Tevar (2016). Dual Chamber Stent Prevents Organ Malperfusion in a Model of Donation after Cardiac Death. Surgery, 160(4), 892–901.
Y. Chen, S.P. Emery, X. Gu, W.R. Wagner, A.P. Maxey, and Y. Chun (2016). A Novel Low-Profile Ventriculoamniotic Shunt for Fetal Aqueductal Stenosis. Journal of Medical Engineering & Technology, 40(4), 186–198.
D. Sadowsky, R. Zamora (2016). Machine Perfusion of Porcine Livers with Oxygen-Carrying Solution Results in Reprogramming of Dynamic Inflammation Networks, Frontiers in Pharmacology Volume 7 article 413.
S.A. Karangwa, P. Dutkowski (2016). Machine Perfusion of Donor Livers for Transplantation: A Proposal for Standardized Nomenclature and Reporting Guidelines, American Journal of Transplantation.
2015
Emery SP, Hogge A, Hill L. Accuracy of prenatal diagnosis of Aqueductal stenosis. Prenatal Diagn 2015;35(4)319-324. PubMed PMID 28348557
Emery SP, Greene S, Hogge WA. Fetal therapy for isolated Aqueductal stenosis. Fetal Diagn Ther 2015;38(2):81-85. PubMed PMID 25997519
2014
P. Fontes, M. Lopez (2014). Liver Preservation with Machine Perfusion and a Newly Developed Cell-Free Oxygen Carrier, American Journal of Transplantation.
G. Jefferies, Y. Mussin (2014). Pre-clinical Evaluation of an Adult Extracorporeal Carbon Dioxide Removal System with Active Mixing for Pediatric Respiratory Support, Int J Artificial Organs.
M. Rojas, N. Cardenes (2014). Human Adult Bone Marrow Derives Stem Cells Decrease Severity of Lipopolysaccharide-induced Acute Respiratory Distress Syndrome in Sheep, Stem Cell Research and Therapy.
A. Sanz, T. Hoppo (2014). In Vivo Assessment of a Biological Occluder for NOTES Gastrotomy Closure, Surgical Laparoscopy Tech Volume 24 Number 4.
2012
P. Wearden, W. Federspiel (2012). Respiratory Dialysis with an Active-Mixing Extracorporeal Carbon Dioxide Removal System in a Chronic Sheep Study, Intensive Care Medicine.
A. Nieponice, T. Gilbert (2012). Bone Marrow-Derived Cells Participate in the Long-term Remodeling in a Mouse Mosel of Esophageal Reconstruction, Journal of Surgical Research.
T. Gilbert, S. Badylak (2012). Prevention of Seroma Formation with TissuGlu Surgical Adhesive in a Canine Abdominoplasty Model: Long Term Clinical and Histologic Studies, Journal of Plastic, Reconstructive, & Aesthetic Surgery.
2011
B. Brown, W. Chung (2011). Extracellular Matrix as an inductive Template for Temporomandibular Joint Meniscus Reconstruction: A Pilot Study, American Association of Oral and Maxillofacial Surgeons.
T Maul, E. Kocylidirim (2011). Pre-clinical Implants of the Levitronix PediVAS Pediatric Ventricular Assist Device: Strategy for Regulatory Approval, Biomedical Engineering Society.
T. Maul, E. Kocylidirim (2011). In Vitro and In Vivo Performance Evaluation of the Second Developmental Version of the PediaFlow Pediatric Ventricular Assist Device, Cardiovascular Engineering and Technology.
C. Johnson, P. Wearden (2011). Platelet Activation in Ovine Undergoing Sham Surgery or Implant of the Second Generation PediaFlow Pediatric Ventricular Assist Device, Artificial Organs Journal.
C. Johnson, V. Shankarraman (2011). Platelet Activation After Implantation of the Levitronix PediVAS in the Ovine Model, ASAIO Journal.